8

• Note the location and function of all control cables landed on the circuit

board on top of the processor housing. Label cables if necessary.

These control cables may now be disconnected from the circuit board.

Disconnect the “TOP COLUMNS” and “BOTTOM COLUMNS” control

cables making sure they have their respective labels.

• The processor housing can now be carefully withdrawn from the rack,

threading the control cables out from under the plexiglass cover.

The back end must be supported as it is withdrawn so the power

connector (square, white, 12-position connector) located at the left rear

can be disconnected. To disconnect, squeeze the tabs on both sides of

the connector together and pull out. The processor housing may now be

fully removed and set aside.

• Unscrew and remove the blank panel located under the slot for the

processor housing.

• Unscrew and remove the air filter grill on the fan housing located above

the slot for the processor housing.

• Unscrew and remove the fan housing. There is a Molex connector at

the rear of the fan housing that must be disconnected. This connector

and cable is not required on the CD-3000 retrofit and should be coiled

up and wire-tied to the wiring harness it emerges from. Keep it isolated

from any AC line voltage.

• With everything removed, look at the fuse block in the back of the rack

and check the phasing. The wires landed on the bottom of the fuse

block lead to the processor power connector. The black wire should

be on Phase “A”, red on Phase “B”, and blue on Phase “C”. Correct if

necessary.

Installation of the new CD-3000-SV System

• Remove your new CD-3000-SV system from the box. Leave the foam

end caps in place to protect the unit from damage.

• Familiarize yourself with the backplane, and low voltage control input/

output connections. Refer to page 12 for details.

• Dress out all DMX and other low voltage connections to the backplane

using the breakaway connectors provided. Be sure to isolate and protect

all shield wires.

• Place the CD-3000-AE in front of the rack face down / backplane up.

Leave the foam end caps left in place to protect the unit from

damage.

• Connect the “TOP COLUMNS” and “BOTTOM COLUMNS” control

cables to their designated locations on the backplane. Lock in place

using the ejection clamps on the connector. Refer to page 11 for the

connector pinout.