Detailed programming – Johnson Systems CD-3000 Series Retrofit Control System User Manual

Page 20

Advertising
background image

www.johnsonsystems.com

20

Detailed Programming

of System Configuration Menu Items

NOTE:

The programming switches can be locked out to prevent inadvertent configuration

changes. To toggle between “LOCKED!!” and “UNLOCKED” press and hold down the EXECUTE

and then ESCAPE switches at the same time for 4-5 seconds.

The sequence of the following system configuration menu items appear as the MENU DOWN (

) switch

is pressed. Pressing the MENU UP (

) switch will sequence the system configuration menu items in the

opposite order. Pressing and holding either of the MENU UP/DOWN (

) switches will speed up the scroll

rate, which can be helpful to speed up the configuration time.
1. SCENESET

Enable and setup 20 different backup scenes.

When scene mode is activated the selected scene will be held with no timeout until

the menu is exited. The 96 control channel levels are configured within the menu and

can be modified on the fly. Scene mode is useful when an external controller is not

available and independent internal control is required.

Press EXECUTE to enter the menu and activate scene mode.

SCENE>01

Displays the scene (01) to be activated.

SCENE>20

Press MENU ( ) to select a different scene from 01 to 20.

CTRL: ON

Control (CTRL) is ON via the selected scene.

CTRL:DMX

Control (CTRL) is via DMX and takes priority over scene mode.

CTRL:HLD

Control (CTRL) is via DMX status hold (HLD) and takes priority over scene mode.

SCENE>20

Press EXECUTE to activate the selected scene.

SCENE:20

The colon (:) flashes twice per second while fading to the selected scene.

SCENE:20

The colon (:) stops flashing when fade is complete and the selected scene is active.

SCENE>20

Press MENU ( ) to select a different scene from 01 to 20.

SCENE 20

Press EXECUTE to modify the selected scene.

C>01L 00

The second line on the LCD indicates the control channel (C) and level (L).

C>96L 00

Press MENU ( ) to select the control channel (C) to modify from 01 to 96.

C 96L>00

Press EXECUTE to toggle from channel (C>) to level (L>) selection.

C>96L 00

Press ESCAPE to toggle from level (L>) to channel (C>) selection.

C 96L>FL

Press MENU ( ) to select the output level (L) for the selected channel from 00 to FL.

CLEAR???

Press EXECUTE to clear the selected preset, and set all channels to 00 level.

SURE ???

Press EXECUTE if you are sure to clear the selected preset.

DONE !!!

Indicates the selected preset has been cleared.

WAIT...

Press ESCAPE to exit and the menu and save programmed scene levels.

Press ESCAPE to back-up within the menu, or exit/deactivate scene mode.

Press RESET to exit scene mode without saving programmed scene levels.

NOTE: When scene mode is activated: DMX and DMX status hold (SH TIME)

automatically takes precedence over scene mode. The analog input levels are

merged (HTP) with the scene levels. If the analog inputs are configured for load

shed mode the inputs will take precedence over the active scene. The security

alarm (S-ALARM) input is merged (HTP) with the scene levels while the fire alarm

(F-ALARM) input automatically takes precedence. Scene mode (SCENEMOD) and

the auxiliary input (AUX IN) are temporarily enabled. Scene mode will only activate

dimmers assigned to room “A”.

2. FADETIME

Set the fade time for each of the 20 scenes from 0 to 99 seconds.

The factory default is 5 seconds for all 20 presets.

Press EXECUTE to enter the menu.

S>01T 05

Displays the scene (S>01) and assigned fade time (T 05).

S>20T 05

Press MENU (

) to select a different scene from 01 to 20.

S 20T>05

Press EXECUTE to toggle between scene (S>) and fade time (T>) selection.

S 20T>99

Press MENU (

) to select a different fade time from 00 to 99 seconds.

Press ESCAPE to exit the menu and save the selected fade time.

Press RESET to exit the menu without saving.

The menu will automatically timeout after 5 minutes of inactivity and save.