Johnson Systems CD-3000 Series Retrofit Control System User Manual

Page 9

Advertising
background image

www.johnsonsystems.com

9

• Connect all other applicable low voltage control input/output connections

to the backplane.

• Connect the power connector (square, white, 12-position connector) into

its mate mounted on the CD-3000-SV chassis. The connector is keyed

so it can only be inserted one way. Push the connector in until a “click”

is heard and the clamps locked indicating that the connector is fully

seated. Refer to page 11 for the connector pinout.

• Carefully slide the CD-3000-SV into the rack using the rails for the

old fan housing. Be sure not to pinch or stress any wires or cables.

Secure in place using the four (4) 10-32 x 3/8” screws provided.

• Place the new air filter grill assembly over the bottom opening of the

rack. Secure in place using the four (4) 10-32 x 1 3/4” screws provided.

The air filter grill assembly is precisely engineered to allow for safe air

flow and filtration. The air filter and frame can be easily removed for

cleaning and maintenance. Pushing up on the filter frame will free it to

be pivoted out. Always ensure the filter frame is fully seated and secure

before installing the CD-3000 air filter grill assembly. The air filter should

be removed from the rack and cleaned annually using compressed air.

WARNING! Never connect power with the air filter grill assembly removed.

• Connect (turn on) the power supply to the Strand CD80

®

dimmer rack(s)

and CD-3000.

• Verify system status LED indicators and LCD display.

Refer to page 17 and 18 for details.

• Refer to the programming section of this manual for system setup.

Refer to page 19 to 34 for details.

• Test the system thoroughly to ensure all wiring terminations are

functioning and the control signals to the dimmers have the correct

phase referencing.

• Verify fan operation. The fans are triggered on at 6% DMX input control,

and stay on as long as the DMX is at 6% or greater. When the DMX

input is brought down below 6%, there is a 5 minute timeout for the fans

to turn off.

CD-3000-SV-48RR

• In development.

CD-3000-SV-96RR

• In development.

CD-3000-C21

• In development.

Advertising