www.johnsonsystems.com

24

For a more complex example, if DIM# is 049, DMX is 321, and #DIM is 024, then

dimmer outputs 049 thru 073 are addressed sequentially to DMX channels 321 thru 344.

Using a combination of MANUAL and BLOCK patching methods can speed up

configuration. Typically, a BLOCK of dimmers is first patched and then edited using

the MANUAL patch.

The DMX patch should be cleared (CLEAR) before configuring the patch. Clearing

the patch ensures all previously configured patch data is cleared (erased).

When DMXA PAT is utilized in conjunction with DMXB PAT, each of the 96 dimmer

(PWM) outputs can be patched to (controlled from) any DMX input channel from 001

to 512, from either or both of the DMX A and DMX B inputs simultaneously.

If a dimmer is patched to both DMX A and DMX B input channels, the DMX levels are

merged and highest-takes-precedence (HTP).

Press EXECUTE to enter the menu and configure the DMX A patch.

Press MENU (

) to scroll through and select the patching method.

MANUAL?

Press EXECUTE to patch each of the dimmers manually (MANUAL).

DIM DMXA

The top line shows the dimmer (DIM) and (DMXA) address headings.

001<999?

The second line shows the dimmer (DIM) and (DMXA) address values.

096<999?

Press MENU (

) to select the dimmer (DIM) from 001 to 096 to patch.

001<999?

Press MENU (

) and MENU (

) at the same time to toggle back to 001.

001

999?

Press EXECUTE to advance and select the DMXA address for the dimmer.

001

999?

DMXA is initialized at 999 to indicate the dimmer is not patched.

001

999?

? indicates the DMXA address (513 to 999) is invalid and is not patched.

001

999?

The cursor (_) position indicates the DMXA digit to be edited.

001 999?

Press EXECUTE to move the cursor to the right, under the digit to be edited.

001

999?

Press ESCAPE to move the cursor to the left or to exit the menu.

001 512

Press MENU (

) to select the DMXA address from 001 to 512.

001 999?

Press MENU (

) and MENU (

) at the same time to toggle back to 999.

Repeat until all required dimmers are manually patched.

BLOCK?

Press EXECUTE to patch the dimmers in a sequential block (BLOCK).

DIM#:001

Press EXECUTE to select the first dimmer number (DIM#) in the block.

DIM#:096

Press MENU (

) to edit the dimmer number (DIM#) from 001 to 096.

DIM#:001

Press MENU (

) and MENU (

) at the same time to toggle back to 001.

DMXA:001

Press EXECUTE to select the DMX A (DMXA) start address for the block.

DMXA:512

Press MENU (

) to edit the DMX A (DMXA) start address from 001 to 512.

DMXA:001

Press MENU (

) and MENU (

) at the same time to toggle back to 001.

#DIM:001

Press EXECUTE to select the number of dimmers (#DIM) in the block.

#DIM:096

Press MENU (

) to edit the number of dimmers (#DIM) from 001 to 096.

#DIM:001

Press MENU (

) and MENU (

) at the same time to toggle back to 001.

PROCEED?

Press EXECUTE to proceed.

SURE ???

Press EXECUTE to proceed.

DONE !!!

Indicates the sequential block patch has been completed.

Repeat until all required blocks of sequential dimmers have been patched.

Press ESCAPE to exit the menu.

CLEAR???

Press EXECUTE to clear the entire patch.

SURE ???

Press EXECUTE to proceed.

DONE !!!

Indicates the entire patch has been cleared.

Press ESCAPE to exit the menu and save the selected patch.

Press RESET to exit the menu without saving.

The menu will automatically timeout after 5 minutes of inactivity and save.

NOTE: Be sure to BACKUP any configuration changes!

NOTE: With DMX patch mode activated, any configuration within the ADDRESS,

DMX MODE, 2 RM SET and DC PATCH menus is ignored, and the DMX patch

configured within this menu takes precedence.