English – Klein Tools CL3000 User Manual

Page 4

Advertising
background image

CUSTOMER SERVICE

KLEIN TOOLS, INC.

450 Bond Street

Lincolnshire, IL 60069

1-877-775-5346

www.kleintools.com

139563T

ENGLISH

WARRANTY

This product is warranted to be free from defects in materials and workmanship
for a period of two years from the date of purchase. During this warranty period,

Klein Tools has the option to repair or replace or refund the purchase price of
any unit which fails to conform to this warranty under normal use and service.

This warranty does not cover damage which occurs in shipment or failure which
results from alteration, tampering, accident, misuse, abuse, neglect, or improper

maintenance. Batteries and damage resulting from failed batteries are not

covered by warranty. A purchase receipt or other proof of original purchase date
will be required before warranty repairs will be rendered.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the express

warranty. Klein Tools shall not be liable for loss of use of the instrument or other

incidental or consequential damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses or economic loss.
Some states or countries laws vary, so the above limitations or exclusions may
not apply to you. This warranty gives you specific legal rights, and you may also

have other rights which vary from state to state. If your Klein product requires

repair or for information on how to exercise your rights under the terms of this
warranty, please contact Klein Tools at 1-877-775-5346.

CLEANING

Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.

STORAGE

Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.

DISPOSAL / RECYCLE

Caution:

This symbol indicates that equipment and its accessories

shall be subject to a separate collection and correct disposal.

Resistance Measurement

Range

Resolution

Accuracy

400

Ω

0.1

Ω

± (1.2% + 1 digit)

4k

Ω

0.001k

Ω

40k

Ω

0.01k

Ω

400k

Ω

0.1k

Ω

4M

Ω

0.001M

Ω

40M

Ω

0.01M

Ω

± (2.0% + 3 digits)

Overload Protection:

250V DC / AC RMS

Capacitance Measurement

Range

Resolution

Accuracy

40nF

0.01nF

± (4.0% + 10 digits)

400nF

0.1nF

4µF

0.001µF

40µF

0.01µF

Overload Protection:

250V DC / AC RMS

Frequency Measurement

Range

Resolution

Accuracy

40Hz

0.01Hz

± (2.0% + 1 digit)

400Hz

0.1Hz

4kHz

0.001kHz

40kHz

0.01kHz

100kHz

0.1kHz

± (10% + 10 digits)

Measurement Voltage Range:

1V to 10V RMS

Minimum Frequency:

10Hz

Duty Cycle Measurement

Range

Resolution

Accuracy

0.1 ˜ 99.9%

0.1%

± (1.0% + 0 digits)

Overload Protection:

600V DC / AC Peak

Diode Test

Overload Protection

Forward DC Current

Reverse DC Voltage

250V RMS

0.6mA

1.5V

Continuity Test

Overload Protection

Open Circuit Voltage

250V RMS

0.4V

Advertising