Function instructions – Klein Tools CL2300 User Manual

Page 4

Advertising
background image

600V

400V

CATIII

600V

400V

CATIII

PRESS

PRESS

2300

7

5

2

3

6

1

9

1.

AC/DC Current (large): < 600A

Features:

2.

AC / DC Current (small): < 2000µA

Features:

MAX/MIN

RANGE

HOLD

H. I. Battery Replacement

• When

indicator is displayed on the LCD, batteries must be

replaced.

• Remove the back screw and replace 2 x AAA batteries.

J.

Magnetic Back

• Attach instrument to metal for hands-free use.

K.

Bar Graph

• The bar graph shows an approximate analog representation

of a measurement.

• The bar graph responds much faster than the digital display.

• The scale of the bar graph is zero to the maximum reading of

the selected range.

L.

Temperature Adjustment

• Remove battery cover.

• Place temperature probe in distilled

water with stirred crushed ice

(a standard for 0°C and 32°F).

• Use a fi ne tip screwdriver to adjust

the screw recessed in the bottom

right corner of the battery cavity as

shown until the display reads 32°F.

FUNCTION INSTRUCTIONS

• Select AC or DC current source.

Current above 2000µA will damage instrument.

MAX/MIN

RANGE

HOLD

• Center wire in guides for best accuracy.
• Opposing currents cancel (use line-splitter when necessary).

ZERO (DC)