ELECTRICAL SPECIFICATIONS

DC Voltage Measurement

Range

Resolution

Accuracy

600mV ˜ ˜ 600V

0.1mV ˜ 100mV

± (0.5% + 4 digits)

1000V

1V

± (0.8% + 10 digits)

Overload Protection:

1000V

AC Voltage Measurement

Range

Resolution

Accuracy

600mV ˜ ˜ 750V

0.1mV ˜ ˜ 1V

± (2.0% + 5 digits)

Overload Protection:

750V RMS

Frequency Response:

45 to 400 Hz

Minimum Voltage for Frequency Measurement:

200mV

Response:

True RMS

DC Current Measurement

Range

Resolution

Accuracy

600µA

0.1µA

± (1.2% + 3 digits)

2000µA

1µA

60A

0.01A

± (2.5% + 15 digits)

600A

0.1A

± (1.5% + 8 digits

Overload Protection:

Voltage:

600V RMS

Current:

2000µA Clamp 600A

AC Current Measurement

Range

Resolution

Accuracy

600µA

0.1µA

± (2.0% + 5 digits)

2000µA

1µA

± (1.5% + 5 digits)

60A

0.01A

± (2.9% + 15 digits)

600A

0.1A

± (1.9% + 8 digits)

Overload Protection:

Voltage:

600V RMS

Current:

2000µA Clamp 600A

Frequency:

45 to 400Hz

Minimum Current for Frequency Measurement:

400µA or 20A

Minimum Current for Clamp Measurement: 0.2A

Response:

True RMS

Resistance Measurement

Range

Resolution

Accuracy

600

˜ 6M

˜˜

0.1

˜ 1k

˜˜

± (1.0% + 4 digits)

60M

10k

± (2.0% + 4 digits)

Overload Protection:

600V RMS

Capacitance Measurement

Range

Resolution

Accuracy

60nF ˜ 6000µF

˜˜

0.01nF ˜ 1µF

˜˜

± (3.5% + 6 digits)

Overload Protection:

600V RMS

Frequency Measurement (Voltage)

Range

Resolution

Accuracy

99.99Hz ˜ 499.9kHz

˜˜

0.01Hz ˜ 100Hz

˜˜

± (0.1% + 4 digits)

Overload Protection:

600V RMS

Sensitivity:

2.5V RMS