Basic settings, Settings – Lenze 8400 motec Mounting Instructions User Manual
Page 55

Settings
Basic settings
l
55
EDK84DGDVBxxx4 DE/EN/FR/ES/IT 5.3
6.1
Basic settings
Possible settings with DIP1
(Lenze setting bold)
DIP1
Switch
Description
1
2
3
4
5
6
7
8
Settings after DIP1, DIP2, P1, P2,
and P3 active
on ( I )
ON
off ( 0 )
OFF
Direction of rotation
left
ON
right
OFF
Control
quadratic
ON
linear
OFF
Flying restart circuit
on ( I )
ON
off ( 0 )
OFF
Reserved
−
OFF OFF OFF
Message type −> on
(only optional with
Communication Unit "+ Safety")
fail −> DO
ready −> NO (relay)
ON
ready −> DO
fail −> NO (relay)
OFF
Possible settings with DIP2
DIP2
Switch
Description
1
2
3
4
5
6
7
8
Rated motor frequency
50 Hz
OFF OFF
60 Hz
ON OFF
87 Hz
OFF ON
120 Hz
ON
ON
Mode of the analog input
(only optional with
Communication Unit "+ Safety")
0 ... 10 V
OFF OFF
0 ... 20 mA
ON OFF
4 ... 20 mA
OFF ON
not permissible
ON
ON
Control mode of technology
application
(cf. selection C00007)
9 (local mode)
OFF OFF OFF
10 (terminals 0)
ON OFF OFF
12 (terminals 2)
OFF ON OFF
14 (terminals 11)
ON
ON OFF
16 (terminals 16)
OFF OFF ON
Reserved
ON OFF ON
Reserved
OFF ON
ON
40 (MCI)
ON
ON
ON
Reserved
−
OFF