Commissioning, Commissioning 7 – Lenze 8400 motec Mounting Instructions User Manual

Page 61

Advertising
background image

Commissioning

7

l

61

EDK84DGDVBxxx4 DE/EN/FR/ES/IT 5.3

7

Commissioning

Preconditions for initial switch−on

ƒ

The wiring unit is mounted and wired according to the instructions,

–

directly on a motor clamping flange or

–

with the wall adapter on a suitable surface near the motor.

ƒ

Connections with the mains, motor, holding brakes, etc. have been
established.

ƒ

The communication unit has been mounted and wired according to the
scheduled application.

–

Input and output signals

–

Safe input

–

Fieldbus

(depending on the version, only available optionally)

ƒ

If required, the basic settings for "local mode" have been carried out.

–

DIP switches

–

Potentiometer

ƒ

The drive unit has been mounted and screwed together.

ƒ

Use available control functions reasonably, e.g.

–

Inhibit controller enable

–

Set speed adjustment to the minimum setting

–

Activate safety system

ƒ

The use of a brake resistor has been checked.

–

In the case of dynamic loads or difficult control conditions, the use of the
internal brake resistor E84DZEW47R0 is always recommended for the
devices E84DGDVB4024 ... 7524 (4 ... 7.5 kW).

}

Danger!

High hazard potential during commissioning

Incorrect settings may cause unexpected and dangerous motor and
system movements.
Possible consequences:

ƒ

Damage to material assets

ƒ

Injury to persons

Protective measures:

ƒ

Clear hazardous area

ƒ

Observe safety instructions and safety clearances