44

EDK94ASH24 DE/EN/FR/ES/IT 4.1

Overview

Standard device

0

Design

Pos.

Description

HighLine

StateLine

MXI1

Module receptacle for extension 1, e.g. communication

ю

ю

MXI2

Module receptacle for extension 2, e.g. communication

þ

o

MMI

Module receptacle for memory modules

ю

ю

MSI

Module receptacle for safety modules

ю

ю

X1

System bus (CAN), under the cover

þ

o

X2

24−V supply and state bus

ю

ю

X3

Analog inputs and analog outputs

2/2

1/0

X4

Digital outputs

4

1

X5

Digital inputs

8

4

X6

Diagnostics

ю

ю

X7

Resolver

ю

ю

X8

Encoder

ю

ю

2

Lower cap

ю

ю

3

Nameplate, retractable

ю

ю

4

Upper cap

ю

ю

8

EMC clamp

1

1

:

Warning sticker − place close to the device in a clearly visible manner!

ю

ю

The LED display enables fast indication of several operating states.

LED

Labelling

Colour

Description

CAN−RUN

green

CAN bus o.k.

Inoperable when "StateLine" design is
used

CAN−ERR

red

CAN bus error

DRIVE READY

green

Standard device is ready for operation

DRIVE ERROR

red

Error in the standard device or due to the application

24 V

green

24−V supply voltage o.k.

SSP94LED01

USER

yellow

Message parameterised by the application

Pos.

Symbol

Description

5

{

Long discharge time: All power terminals carry hazardous voltages for at
least 3 minutes after mains disconnection!

}

High discharge current: Fixed installation and PE connection to EN 61800−5−1
required!

'

Electrostatic sensitive devices: Before working on the device, personnel must
ensure that they are free of electrostatic charge!

Installation backplane

1

Design

Pos.

Description

HighLine

StateLine

X100

Mains / DC−bus voltage

þ

X105

Motor / external brake resistor

þ

X106

Motor temperature monitoring

þ

X107

Control of motor holding brake

Optional

X109

DC busbar +

Optional

(for DC−bus connection)

X110

DC busbar −

6

EMC wire clamp (for device sizes II + III), replaces 1x

7

1

7

EMC shield clamp

3 or 2

© 2010 Lenze Automation GmbH, Hans−Lenze−Str. 1, D−31855 Aerzen
No part of this documentation may be reproduced or made accessible to third parties without written consent by Lenze Automa-
tion GmbH.
All information given in this documentation has been selected carefully and complies with the hardware and software described.
Nevertheless, discrepancies cannot be ruled out. We do not take any responsibility or liability for any damage that may occur. Ne-
cessary corrections will be included in subsequent editions.