4 example circuit, Example circuit 4, 4example circuit – Lenze 9400 Mounting Instructions User Manual
Page 58

Example circuit
4
l
58
EDK94ASH24 DE/EN/FR/ES/IT 4.1
4
Example circuit
L3
N
PE
L1
L2
F1...F3
Z1
F4
K1
K1
K1
L1
L2
L3
E94ASxExxxx
X100
-UG
O
I
RFR
+UG
Rb2
Rb1
R
B
R
B
U V W
X105
BD1
+
BD2
-
X107
X5
T1
GI
RFR
T2
X106
M
3~
R
Y
J
J
2
7
. . .
E94AZPxxxxx
+
-
EYF...
+
-
X7
X3
+
-
A1-
A1+
+
+
SSP94PSP01
E94ASxExxxx
9400 Single Drive servo axis module
E94AZPxxxxx
Installation backplane
F1 ... F4
Fuses
Z1
Mains filter/RFI filter (optional)
"
HF shield termination through large−surface connection to functional earth
EYF...
System cable for resolver feedback
RFR
Controller enable
K1
Mains contactor
R
Resolver
RB
Brake resistor
Y
Motor holding brake (connected to optional motor brake control)
Speed setpoint selection via analog input 1 (−10 ... 0 ... +10 V)
Voltage source for the motor holding brake
24−V voltage source for the digital inputs according to IEC 61131−2