Wiring the device modules

Function modules

8

l

72

EDK94ASH24 DE/EN/FR/ES/IT 4.1

8.2

Function modules

Use these modules in slot

þ MXI1 or þMXI2 oMMI oMSI.

Digital frequency

E94AYFLF004

Connections

Pos.

Description

X9

Input for digital frequency, 9−pole Sub−D plug

X10

Output for digital frequency, 9−pole Sub−D socket

X9

Pin

Designation

Explanation

1

6

5

9

1

B

TTL input signal by encoder or encoder simulation

2

A

3

A

4

+5 V

Regulated voltage supply for encoder
(pin 8 = sense must be used, max. control range 5 ... 9 V)

5

GND

6

Z

TTL input signal by encoder or encoder simulation

7

Z

8

The function of this cable has to be set in the basic device:

l

S

l

Lc

l

E

l

Sense (sensor lead for voltage regulation, Lenze setting)

l

Lamp control

l

Enable

SUBD09010

9

B

TTL input signal by encoder or encoder simulation

Advertising