2 function modules, Wiring the device modules – Lenze 9400 Mounting Instructions User Manual
Page 72
Advertising

Wiring the device modules
Function modules
l
72
EDK94ASH24 DE/EN/FR/ES/IT 4.1
8.2
Function modules
Use these modules in slot
þ MXI1 or þMXI2 oMMI oMSI.
Digital frequency
E94AYFLF004
Connections
Pos.
Description
X9
Input for digital frequency, 9−pole Sub−D plug
X10
Output for digital frequency, 9−pole Sub−D socket
X9
Pin
Designation
Explanation
1
6
5
9
1
B
TTL input signal by encoder or encoder simulation
2
A
3
A
4
+5 V
Regulated voltage supply for encoder
(pin 8 = sense must be used, max. control range 5 ... 9 V)
5
GND
−
6
Z
TTL input signal by encoder or encoder simulation
7
Z
8
The function of this cable has to be set in the basic device:
l
S
l
Lc
l
E
l
Sense (sensor lead for voltage regulation, Lenze setting)
l
Lamp control
l
Enable
SUBD09010
9
B
TTL input signal by encoder or encoder simulation
Advertising