3 technical data, 1 general data and operating conditions, Technical data – Lenze 9400 Mounting Instructions User Manual

Page 53: 3technical data

Advertising
background image

Technical data

General data and operating conditions

3

l

53

EDK94ASH24 DE/EN/FR/ES/IT 4.1

3

Technical data

3.1

General data and operating conditions

Supply system data

Supply forms

With earthed neutral Unrestricted use

IT systems

Observe instructions about special measures!

Noise emission

EN 61800−3

Cable−guided, up to 10 m motor cable length: category C2

Radiation: category C3

Noise immunity

EN 61800−3

Category C3

Conformity and approval

Conformity

CE

2006/95/EC

Low−voltage directive

Approval

UL

UL 508C

Power Conversion Equipment, File No. 132659

GOST−R

51321.1−2000
51321.3−99

No. POCC DE.AN30.B08815

Protection of persons and devices

Enclosure

EN 60529

IP 20

Not in the wire range of
the terminals on the
motor side

NEMA 250

Protection against contact in
accordance with type 1

Insulation resistance

EN 61800−5−1

Overvoltage category III
Reduction from 2000 m amsl onwards: Overvoltage category
II

Insulation of control
circuits

EN 61800−5−1

Safe mains isolation by double/reinforced insulation for
mains with neutral earthing with a rated voltage for the
external conductor/star point up to 300 V.

Short−circuit strength

EN 61800−5−1

Motor connection: with restrictions, error acknowledgement
required
Control connections: without restrictions

Motor − protective
measures against

l

Short circuit

l

Earth fault

l

Overvoltage

l

Motor stalling

l

Motor overtemperature
(PTC or thermal contact, I

2

t monitoring)

Discharge current

EN 61800−5−1

> 3.5 mA AC, > 10 mA DC

Observe regulations and
safety instructions!

Cyclic mains switching

Cyclic mains switching of 5 times in 5 minutes is permissible
without restrictions.

Advertising