Wiring of the standard device
l
62
EDK94ASH24 DE/EN/FR/ES/IT 4.1
I
Tip!
Parameter setting and configuration can be carried out using the
L−force »Engineer«. For this purpose the Online Help and the Software Manual
for the standard device will guide you.
System bus CAN on board
Terminal X1
Labelling
Description
Pin 2
CAN−LOW
Pin 3
CAN−GND
Pin 7
CAN−HIGH
9400SSP000X1
(Housing)
CAN−Shield
)
Note!
The X1 connection is not available in the "StateLine" design.
24 V supply
Terminal X2
Labelling
Description
GE
GND external supply
24E
24 V external supply via a safely separated power supply
unit (SELV/PELV) (only required for mains−independent supply of the
control electronics)
9400SSP000X2
SB
State bus in/out (reference GE)
Terminal data
Conductor cross−section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb−in]
Flexible
0.2 ... 2.5
24 ... 12
Spring terminal
With wire end
ferrule