2 electrical data, Technical data, Electrical data – Lenze 9400 Mounting Instructions User Manual

Page 55: 2 electrical data input data

Advertising
background image

Technical data

Electrical data

3

l

55

EDK94ASH24 DE/EN/FR/ES/IT 4.1

3.2

Electrical data

Input data

Basis of the data

Mains

Voltage

Voltage range

Frequency range

U

LN

[V]

U

LN

[V]

f [Hz]

3/PE AC

230

180 − 0 % ... 264 + 0 %

45 ... 65

3/PE AC

400

320 − 0 % ... 440 + 0 %

45 ... 65

3/PE AC

500

400 − 0 % ... 550 + 0 %

45 ... 65

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C



max. +55 °C



E94ASxE0024

230/400/500

50/60

2.1/2.1/1.8

1.6/1.6/1.4

3

E94ASxE0034

230/400/500

50/60

3.5/3.5/3.1

2.6/2.6/2.3

3

E94ASxE0044

230/400/500

50/60

5.5/5.5/4.8

4.1/4.1/3.6

3

E94ASxE0074

230/400/500

50/60

9.9/9.9/8.6

7.4/7.4/6.5

3

E94ASxE0134

230/400/500

50/60

16.8/16.8/14.7

12.6/12.6/11.0

3

E94ASxE0174

230/400/500

50/60

21.0/21.0/18.3

15.8/15.8/13.8

3

E94ASxE0244

230/400/500

50/60

29.0/29.0/25.4

21.8/21.8/19.1

3

 Temperature in the control cabinet

Operation in DC−bus connection with optional accessories

Basis of the data

Mains

Voltage

U

DC

[V]

Voltage range

U

DC

[V]

Frequency range

f [Hz]

2/PE DC

325

260 − 0 % ... 370 + 0 %

2/PE DC

565

455 − 0 % ... 620 + 0 %

2/PE DC

705

565 − 0 % ... 775 + 0 %

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C



max. +55 °C



E94ASxE0024

325/565/705

0 ( DC)

2.6/2.6/2.3

2.0/2.0/1.7

2

E94ASxE0034

325/565/705

0 ( DC)

4.3/4.3/3.8

3.2/3.2/2.9

2

E94ASxE0044

325/565/705

0 ( DC)

6.7/6.7/5.9

5.0/5.0/4.4

2

E94ASxE0074

325/565/705

0 ( DC)

12.1/12.1/10.6

9.1/9.1/8.0

2

E94ASxE0134

325/565/705

0 ( DC)

20.6/20.6/18.0

15.5/15.5/13.5

2

E94ASxE0174

325/565/705

0 ( DC)

25.7/25.7/22,5

19.3/19.3/16.9

2

E94ASxE0244

325/565/705

0 ( DC)

35.5/35.5/31.1

26.3/26.3/23.3

2

 Temperature in the control cabinet