Technical data – Lenze E82ZWBRE User Manual

Page 35

Advertising
background image

Technical data

Rated data

3

EDK82ZWBRE DE/EN/FR 6.0

35

l

H1_Daten−E82ZWBRB_Schalthaeufig_Fussnote_EN

Permissible switching rates

Recommended brake

Power

Coil: voltage DC 180 V

Permissible switching rate

Type

P [W]

L [H]

I [A] (20 °C)

[1/min]

BFK457−06E
BFK458−06E

20

60

0.11

60

BFK457−08E
BFK458−08E

25

50

0.14

60

BFK457−10E
BFK458−10E

30

69

0.17

60

BFK457−12E
BFK458−12E

40

81

0.22

40

BFK457−14E
BFK458−14E

50

78

0.28

30

BFK457−16E
BFK458−16E

55

102

0.31

20

BFK457−18E
BFK458−18E

85

77

0.47

10

BFK457−20E

1)

BFK458−20E

1)

100

92

0.56

8

BFK457−25E

1)

BFK458−25E

1)

110

102

0.61

6

1)

Operation only permitted if the brake switch is mounted in the control cabinet

Advertising