5electrical installation – Lenze E82ZWBRE User Manual

Page 42

Advertising
background image

5

Electrical installation

Wiring in the 8200 motec

EDK82ZWBRE DE/EN/FR 6.0

42

l

H1_E_INST−E82ZxBRx_Kabelquer_EN

0

Connection variant 1:

Z1

Standard I/O function module

The internal voltage source of the function module supplies the digital output.
Control of the brake switch via the digital output of the function module.

1

Connection variant 2:

Z1

Application I/O function module

The internal voltage source of the function module supplies the digital output.
Control of the brake switch via the digital output of the function module.

2

Connection variant 3 (only with 8200 motec, variant V152 or V153):

Z1

Function module

The internal voltage source of the function module supplies the digital output of the
motec.
Control of the brake switch via the digital output of the motec.

Note:
Instead of using the internal voltage source of the function module, you can also supply
the digital output of the motec via an external 24 V DC voltage source.

Terminal data

Conductor cross−section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb−in]

Flexible

0.5 ... 1.5

20 ... 16

0.5 ... 0.6

4.5 ... 6.2

With wire end
ferrule

Advertising