Technical data

EDKZV1200 DE/EN/FR/ES/IT 1.0

26

l

H1_Daten−−−−(DUMMYSEITEVOR)−−−

Input data

Power supply unit AC 400 V, DC 24 V

5 A

10 A

20 A

Turn−on time

< 1 s after applying the mains voltage

Transient surge voltage protection

varistor

Mains voltage range

3 AC 320 V − 0 % ... 575 V + 0 %, 45 Hz − 0 % ... 65 Hz + 0 %

Current
consumption

AC 400 V 3 x 0.4 A

3 x 0.6 A

3 x 1.1 A

AC 480 V 3 x 0.3 A

3 x 0.6 A

3 x 1.0 A

Starting current limitation /
I

2

t (+25 °C)

typ. < 15 A /
< 3.0 A

2

s

typ. < 15 A /
< 4.0 A

2

s

typ. < 15 A /
< 1.0 A

2

s

Mains buffering at
rated load

AC 400 V typ. > 50 ms

typ. > 40 ms

typ. > 23 ms

AC 480 V > 50 ms

> 40 ms

> 25 ms

Recommended back−up fuse

Circuit−breaker (charact. B or C)

6 A / 10 A / 16 A

Output data

Power supply unit AC400 V, DC 24 V

5 A

10 A

20 A

Rated output voltage U

N

DC 24 V / ± 1 %

Setting range of the output voltage

DC 22.5 ... 28.5 V

Start of unlimited capacitive loads

yes

Residual ripple / switching peaks (20
MHz)

<

100 mV

SS

at rated values

Can be connected in parallel

to increase redundancy and power

Resistance to return supply

DC 35 V

l

Output current I

BOOST

at

– convection cooling
– V

rated

– −25 ... +40 °C

7.5 A

15 A

27 A

l

Rated output current I

rated

at

– convection cooling
– V

rated

– −25 ... +60 °C

5 A

10 A

20 A

Current limitation in case of short
circuit

< 7.5 A

< 15 A

< 27 A