Technical data

General data and operating conditions

4

l

27

EDK94AZCDM DE/EN/FR/ES/IT 1.0

4

Technical data

4.1

General data and operating conditions

Conformity and approvals

Conformity

l

CE

2006/95/EG Low−Voltage Directive
2004/108/EG EMC Directive

Approval

l

UR

UL508C: Industrial Control Equipment
Lenze File No. 132659

Protection of persons and devices

Type of protection

EN 60529 IP 20

Insulation resistance

EN 61800−5−1

l

< 2000 m amsl: Overvoltage category III

l

> 2000 m amsl: Overvoltage category II

Insulation of control circuits

EN 61800−5−1
Safe mains isolation through double/reinforced insulation

EMC

Noise immunity
(according to requirements EN
61800−3)

The controllers are designed for use in an industrial
environment. Operation on public networks requires
measures to be taken for limiting the expected emission of
radio interferences.

l

Electrostatic discharge (ESD)

EN 61000−4−2

8 kV for air discharge,
4 kV for contact discharge to
housing

l

Radio frequency

– cable−guided

EN 61000−4−6

150 kHz ... 80 MHz, 10 V/m
80% AM (1kHz)

– Interference (housing)

EN 61000−4−3

80 MHz ... 1000 MHz, 10 V/m
80% AM (1kHz)

l

Burst

– Power connections and

interfaces

EN 61000−4−4

2 kV/5 kHz

– Signal interfaces

EN 61000−4−4

1 kV/5 kHz

– Control connections

EN 61000−4−4

2 kV/5 kHz

l

Surge (surge voltage)

– Power terminals

EN 61000−4−5

1.2/50

ms,

1 kV phase/phase,
2 kV phase/PE

Noise emission, cable−guided

Observe the information of the hardware manual of the
Servo Drive 9400 (EDS94SPP101) version.
C2 acc. to EN 61800−3

Advertising