Electrical installation, Minimum wiring, 5electrical installation – Lenze E94AZCDM100 User Manual

Page 30: 1 minimum wiring

Advertising
background image

Electrical installation

Minimum wiring

5

l

30

EDK94AZCDM DE/EN/FR/ES/IT 1.0

5

Electrical installation

5.1

Minimum wiring

L3

N

L1
L2

F2...F4

K1

L1 L2

L3

X100

-UG

+UG

+

E94AZCDMxxx

5

4

-A2

+K1

3

+A1

-K2

1 2

J

F5...F7

F1

K1

O

I

J

PE

L1 L2

L3

X100

-UG

+UG

+

U

Rb1 Rb2

V W

X105

+

E94AZCDM100

E94ASxE0864

E94ASxE6954

...

Z1

R

B

R

B

E94ASxE0024

E94ASxE0594

...

+

24 V

GND

F8 F9

F10 F11

Z2

SSP94NF002

Fig. 5−1

9400 power system with E94AZCDMxxx diode module

K1

Mains contactor

F1 ... F7

Fuse

F8 ... F11

DC fuse

Z1, Z2

Mains choke

)

Note!

In case of braking operation or regenerative feedback, the brake
module or regenerative module must always be connected to the
group with the „smallerˆ servo controllers.

When a diode module is used, the starting current is only admitted by devices
of type 7 and bigger towards the devices BF6 and smaller.
The starting current limitations of both devices oppose this current. Thus, it can
be assumed that each device charges its own DC−bus capacitor.

Advertising