Technical data – Lenze E94AZMP User Manual

Page 45

Advertising
background image

Technical data

General data and operating conditions

4

l

45

EDK94AZMP45 DE/EN/FR/ES/IT 7.0

Environmental conditions

Climate

Storage

IEC/EN 60721−3−1

1K3 (−25 ... +60 °C)

Transport

IEC/EN 60721−3−2

2K3 (−25 ... +70 °C)

Operation

IEC/EN 60721−3−3

3K3 (−10 ... +55 °C)
Current derating at +45 ... +55 °C: 2.5 %/°C

Site altitude

0 ... 4000 m amsl
1000 ... 4000 m amsl: current derating of
5 %/1000 m

Pollution

EN 61800−5−1

Pollution degree 2

Vibration resistance

(9.81 m/s

2

= 1 g)

Transport

IEC/EN 60721−3−2

2M2

EN 61800−2

2 ... 9 Hz: amplitude 3.5 mm

10 ... 200 Hz: acceleration resistant up to 10 m/s

2

200 ... 500 Hz: acceleration resistant up to 15 m/s

2

Operation

Germanischer
Lloyd

5 ... 13.2 Hz: amplitude ±1 mm
13.2 ... 100 Hz: acceleration resistant up to 0.7 g

IEC/EN 60068−2−6

10 ... 57 Hz: amplitude 0.075 mm

57 ... 150 Hz: acceleration resistant up to 1 g

Mounting conditions

Mounting place

In the control cabinet

Mounting position

Vertically

Free space

The required free space results from the mounting
position and the specifications of the standard
device.

Mounting position

Standard

Side−by−side mounting; filter is directly screwed to
the left of the standard device (

^Mechanical

installation)

Variant

Top mounting; the filter is screwed on top of the
basic device (

^Mechanical installation)

Advertising