Technical data

Rated data

4

l

46

EDK94AZMP45 DE/EN/FR/ES/IT 7.0

4.2

Rated data

Mains

Voltage

Voltage range

Frequency range

U

Lrated

[V]

U

Lrated

[V]

f [Hz]

3/PE AC

230

180 − 0 % ... 264 + 0 %

45 − 0 % ... 65 + 0 %

3/PE AC

400

320 − 0 % ... 440 + 0 %

45 − 0 % ... 65 + 0 %

3/PE AC

500

400 − 0 % ... 550 + 0 %

45 − 0 % ... 65 + 0 %

Voltage

Freq.

Current [A]

Current [A]

Number

of phases

[V]

[Hz]

 max. +45° C

 max. +55° C

E94AZMP0824

230/400/500

50/60

82/82/82

61/61/61

3

E94AZMP2004

230/400/500

50/60

200/200/200

150/150/150

3

E94AZMP0824

2)

400/500

50/60

49/49

30.6/30.6

3

 Temperature in the control cabinet

2)

For i700 mounting: mains connection at the bottom, output at the top

Power loss

Inductance

Voltage drop

P

loss

[W]

L [mH]

DU [V]

E94AZMP0824

200

0.25

6.4

E94AZMP2004

350

0.10

6.3

Thermal contact

Design

max. switching voltage

max. switching current

U

Th

[V AC]

I

Th

[A]

E94AZMP0824

NC contact, 150 °C

250

2.5

E94AZMP2004

Fan

Voltage

Current

[V DC]

[A]

E94AZMP0824

24

0.3

E94AZMP2004