Lenze E94ASHE Axis Single Drive 32-104A User Manual
Page 61
Advertising

Wiring the device
Important notes
l
61
EDK94SH104 DE/EN/FR/ES/IT 5.1
(
Stop!
No device protection if the mains voltage is too high
The mains input is not internally fused.
Possible consequences:
ƒ
Destruction of the device if the mains voltage is too high.
Protective measures:
ƒ
Observe the maximally permissible mains voltage.
ƒ
Fuse the device correctly on the supply side against mains fluctuations and
voltage peaks.
)
Note!
Switching operations on the motor side of the controller are permitted for
safety switch−off (emergency off).
Please observe:
ƒ
When the controller is enabled, switching operations may lead to a response
of the controller monitoring functions.
ƒ
The switching elements on the motor side must be rated for DC voltages
with U
DCmax
= 800 V.
Advertising