Wiring the device – Lenze E94ASHE Axis Single Drive 32-104A User Manual
Page 67

Wiring the device
Power terminals
l
67
EDK94SH104 DE/EN/FR/ES/IT 5.1
Motor temperature monitoring
Terminal X106
Labelling
Description
T1
T2
Motor temperature monitoring with PTC element (type−A sensor,
switching performance according to EN 60947−8 for type−A tripping units)
or thermostat (NC contact).
SSP94X6106
Terminal data
Max. conductor cross−section
Tightening torque
!
[mm
2
]
[AWG]
[Nm]
[lb−in]
Flexible
2.5
12
0.5 ... 0.6
4.5 ... 6.2
Slot
0.6 x 3.5
With wire end ferrule
Motor brake control (optional)
Terminal X107
Labelling
Description
Connection of the motor holding brake
BD1
BD2
+ (Lenze: WH)
− (Lenze: BN)
E94AZHY0101: 24 V DC, max. 5.0 A
Observe correct polarity!
+ / −
Supply voltage for the motor holding brake (18 ... 30 V DC)
Observe correct polarity!
SSP94X6107
Terminal data
Max. conductor cross−section
Tightening torque
!
[mm
2
]
[AWG]
[Nm]
[lb−in]
Flexible
2.5
12
0.5 ... 0.6
4.5 ... 6.2
Slot
0.6 x 3.5
With wire end ferrule