l

H2_SpgVersorgg−steckerleisteSchraub2.5

Voltage supply

External supply

The communication module is externally supplied with voltage via the DeviceNet cable at
the 5−pole plug connector (X225).

)

Note!

Use a safely separated power supply unit ("SELV"/"PELV") according to EN
61800−5−1.

ƒ The external voltage supply of the communication module is always required.
ƒ Communication with a standard device which is separated from the mains is not

possible.

Terminal data

Terminal

Cable colour

Description

V+

Red

External voltage supply

l

U = +24 V DC

l

I

max

= 170 mA

V−

black

Reference potential for external voltage supply

Type

Values

Electrical connection

Plug connector with double screw connection

Possible connections

rigid:

2.5 mm

2

(AWG 14)

flexible:

without wire end ferrule
2.5 mm

2

(AWG 14)

with wire end ferrule, without plastic sleeve
2.5 mm

2

(AWG 14)

with wire end ferrule, with plastic sleeve
2.5 mm

2

(AWG 14)

Tightening torque

0.5 ... 0.6 Nm (4.4 ... 5.3 lb−in)

Stripping length

7 mm