3 replacing the lubricant, Replacing the lubricant, Maintenance – Lenze GKK User Manual
Page 24: Stop, Maintenance operations replacing the lubricant, Gearbox should be warm
![background image](/manuals/565835/24/background.png)
Maintenance
Maintenance operations
Replacing the lubricant
7
24
BA 12.0032-EN 2.0
Gearbox type
GSS
GKK07
Gearbox type
GST, GFL, GKS, GKR,
GKK04 ... 06
DIN 51517-3: CLP
ISO 12925-1: CKC/CKD
Ambient temperature [°C]
-50
0
+50
0
+40
CLP
VG 460
Turmogearoil
460 OM
-25
+50
3)
CLP HC
VG 320
Turmofluid GV 320
-20
+40
CLP PG
VG 460
Turmopoloil 460 EP
1)
-20
+40
CLP PG
VG 220
Turmopoloil 220 EP
1)
-40
0
4)
∗∗∗∗
CLP HC
VG 46
Turmofluid GV 46
-20
+40
II
CLP HC
VG 220
Turmosynthoil
GV 220
-20
+40
II
CLP PG
VG 460
Turmosynthoil PG 460
1) 2)
-20
+50
3)
≈≈≈≈
CLP E
VG 320
Turmofluid Biolube
CLP 320
Turmofluid Biolube
CLP 320
1)
0
+40
CLP
VG 460
Optigear BM 460
-25
+50
3)
CLP HC
VG 320
Optigear Synthetic A
320
0
+40
CLP
VG 460
Tribol 1100/460
-20
+40
CLP PG
VG 460
Tribol 800/460
1) 2)
-25
+40
CLP HC
VG 320
Tribol 1510/320
-20
+40
II
CLP
VG 220
Food Proof 1810/220
-20
+50
3)
II
CLP PG
VG 460
Food Proof 1800/460
1) 2)
7.2.3
Replacing the lubricant
Stop!
ƒ
Gearbox should be warm.
ƒ
Secure drive system and machine from inadvertent movement and mains
connection.