4 technical data, General data, Operating conditions – Lenze E82ZAFPC001 User Manual

Page 46: Technical data, 4technical data

Advertising
background image

4

Technical data

General Data

EDK82ZAFPC-001 DE/EN/FR 6.0

46

H1_Daten-IP20

4

Technical data

General Data

Field

Values

Order designation

E82ZAFPC001

PUO ID number

0x00DA

hex

Communication profile
(DIN 19245 part 1 and part 3)

PROFIBUS-DP-V0

Communication medium

RS485

Drive profile

”Drive technology 20” DRIVECOM profile, can be switched off

Network topology

Without repeater: line
With repeater: line or tree

PROFIBUS nodes

Slave

Baud rate [kbps]

9.6 ... 12000 (automatic recognition)

Process data words

1 ... 10 words
(16 bits per word)

DP user data length

4 parameter data words +
1 ... 10 process data words

Max. number of nodes

Standard: 32 (= 1 bus segment)
With repeater: 125

Max. cable length per bus
segment

1200 m (depending on the baud rate and cable type used)

External DC voltage supply

+24 V DC ±10 %, max. 80 mA

Operating conditions

Ambient conditions

Climate

Storage

IEC/EN 60721-3-1

1K3 (-25 to +60 °C)

Transport

IEC/EN 60721-3-2

2K3 (-25 to +70 °C)

Operation

Corresponding to the data of the Lenze standard device used (see
documentation of the standard device).

Pollution

EN 61800-5-1

Degree of pollution 2

Degree of protection

IP20 (protection against accidental contact according to NEMA 250 type 1)

Advertising