8 diagnostics, Led status displays, Diagnostics – Lenze E82ZAFPC001 User Manual

Page 67

Advertising
background image

Diagnostics

LED status displays

8

EDK82ZAFPC-001 DE/EN/FR 6.0

67

H1_Diagnose-Statusanzeige

8

Diagnostics

LED status displays

E82ZAFP008

LED

Description

Pos.

Colour

Condition

yellow

off

No communication with the PROFIBUS master.

blinking

Communication with the PROFIBUS master has been established
via the function module.

green

off

The function module is not supplied with voltage.
The standard device and/or the external voltage supply is
switched off.

blinking

The function module is supplied with voltage but is not connected
to the standard device.
Causes:

The standard device is switched off.
The standard device is in the initialisation phase.
The standard device is not available

on

The function module is supplied with voltage and is connected to
the standard device.



+

yellow/
green

blinking

Internal function module error

Advertising