4 technical data, General data, Operating conditions – Lenze E82ZAFCC010 User Manual
Page 40: Protective insulation, Technical data, 4technical data
![background image](/manuals/565933/40/background.png)
4
Technical data
General Data
EDK82ZAFCC-010 DE/EN/FR 5.0
40
H1_Daten-BemessDat AFCC010
4
Technical data
General Data
Field
Values
Communication profile
Based on CANopen
Communication medium
ISO 11898
Network topology
Line (terminated with 120
Ω
)
on both sides
Node addresses
Max. 63
Baud rate [kbps]
20, 50, 125, 250, 500
Operating conditions
Ambient conditions
Climate
Storage
IEC/EN 60721-3-1
1K3 (-25 to +60 °C)
Transport
IEC/EN 60721-3-2
2K3 (-25 to +70 °C)
Operation
Corresponding to the data of the Lenze standard device used (see
documentation of the standard device).
Pollution
EN 61800-5-1
Degree of pollution 2
Protective insulation
Protective insulation between bus and ...
Type of insulation (in accordance with
EN 61800-5-1)
8200 vector power stage
Reinforced insulation
Reference earth/PE
Functional insulation
Terminal X3.2/20
No functional insulation
Terminal X3.2/28
Functional insulation