4 technical data, General data, Operating conditions – Lenze E82ZAFCC010 User Manual

Page 40: Protective insulation, Technical data, 4technical data

Advertising
background image

4

Technical data

General Data

EDK82ZAFCC-010 DE/EN/FR 5.0

40

H1_Daten-BemessDat AFCC010

4

Technical data

General Data

Field

Values

Communication profile

Based on CANopen

Communication medium

ISO 11898

Network topology

Line (terminated with 120

)

on both sides

Node addresses

Max. 63

Baud rate [kbps]

20, 50, 125, 250, 500

Operating conditions

Ambient conditions

Climate

Storage

IEC/EN 60721-3-1

1K3 (-25 to +60 °C)

Transport

IEC/EN 60721-3-2

2K3 (-25 to +70 °C)

Operation

Corresponding to the data of the Lenze standard device used (see
documentation of the standard device).

Pollution

EN 61800-5-1

Degree of pollution 2

Protective insulation

Protective insulation between bus and ...

Type of insulation (in accordance with

EN 61800-5-1)

8200 vector power stage

Reinforced insulation

Reference earth/PE

Functional insulation

Terminal X3.2/20

No functional insulation

Terminal X3.2/28

Functional insulation

Advertising