Electrical installation
Terminal assignment
6
EDK82ZAFCC-210 DE/EN/FR 4.0
53
H2 BelegungAnschlKlemmen-INS_Klembesch
X3.1/
Designation
Function
Level
7
GND1
Reference potential 1
LO
CAN-LOW
System bus LOW (data line)
HI
CAN-HIGH
System bus HIGH (data line)
X3.2/
Designation
Function
Level
E1
Digital input
User-defined,
can alternatively be used as a frequency
input (see ”Technical data”)
0 = LOW (0 ... +3 V)
1 = HIGH (+12 ... +30 V)
Reference: GND2
E2
Digital input
User-defined
X3.3/
Designation
Function
Level
7
GND1
Reference potential 1
39
GND2
Reference potential 2 for controller
inhibit (CINH) at X3.3/28
28
CINH
Controller inhibit
Start = HIGH (+12 V ... +30 V)
Stop = LOW (0 V ... +3 V)
20
DC voltage source for internal supply of
controller inhibit (CINH)
+ 20 V (Ref: GND1)