2 function blocks, 1 special functions, 1 holding brake (l_brk) – Lenze DDS Function library 9300 Servo User Manual

Page 11: Special functions, Holding brake (l_brk), Function block library lenze9300servo.lib, 2function blocks, Special functions 2.1.1 holding brake (l_brk), Parameter codes of the instances

Advertising
background image

Function block library Lenze9300Servo.lib

Special functions

2.1.1

Holding brake (L_BRK)

2−1

L

Lenze9300Servo.lib EN 1.1

2

Function blocks

2.1

Special functions

2.1.1

Holding brake (L_BRK)

This FB controls a holding brake. You can use it, for instance, for hoists and traversing drives, as well
as for active loads.

DCTRL_bCInh_b

MCTRL_nNAct_a

MCTRL_nNSet2_a

MCTRL_nMAct_a

bSet_b

nNx_a

nSign_a

SIGN

nMSet

t

0

wActivationTime

t

0

wReleaseTime

L_BRK

bQSP_b

bOut_b

bMStore_b

bCInh_b

nMSetOut_a

CTRL

Abb. 2−1

Holding brake (L_BRK)

VariableName

DataType

SignalType

VariableType

Note

bSet_b

Bool

binary

VAR_INPUT

nNx_a

Integer

analog

VAR_INPUT

Speed threshold from which the drive can output the
signal "close brake". The signal source for this input
can be a control code, a fixed value or any other
analog output of a FB.

nSign_a

Integer

analog

VAR_INPUT

Direction of the torque which the drive has to build up
against the brake. The signal source for this input can
be a control code, a fixed value or any other analog
output of a FB.

bQSP_b

Bool

binary

VAR_OUTPUT

QSP can be triggered in conjunction with MCTRL.

bOut_b

Bool

binary

VAR_OUTPUT

Set the brake

bMStore_b

Bool

binary

VAR_OUTPUT

provide a defined holding torque

bCInh_b

Bool

binary

VAR_OUTPUT

A controller inhibit can be set in conjunction with
DCTRL.

nMSetOut_a

Integer

analog

VAR_OUTPUT

Holding torque of the DC injection brake
16384 = value of C0057 (max. possible torque for the
drive configuration)

wReleaseTime

Word

−

VAR CONSTANT RETAIN

Brake disengaging time

wActivationTime

Word

−

VAR CONSTANT RETAIN

Brake engaging time

nMSet

Integer

−

VAR CONSTANT RETAIN

Holding torque

DCTRL_bCInh_b

Bool

−

−

These signals are processed as quantities within the
FB.

MCTRL_nNAct_a

Integer

−

−

MCTRL_nNSet2_a

Integer

−

−

MCTRL_nMAct_a

Integer

−

−

Parameter codes of the instances

VariableName

L_BRK1

SettingRange

Lenze

wReleaseTime

C0196

0.0 ... 60.0 s

0.0

wActivationTime

C0195

0.0 ... 99.9 s

99.9

nMSet

C0244

−199.99 ... 199.99 %

0.00

Advertising