Function block library Lenze9300Servo.lib

Special functions

2.1.1

Holding brake (L_BRK)

2−1

L

Lenze9300Servo.lib EN 1.1

2

Function blocks

2.1

Special functions

2.1.1

Holding brake (L_BRK)

This FB controls a holding brake. You can use it, for instance, for hoists and traversing drives, as well
as for active loads.

DCTRL_bCInh_b

MCTRL_nNAct_a

MCTRL_nNSet2_a

MCTRL_nMAct_a

bSet_b

nNx_a

nSign_a

SIGN

nMSet

t

0

wActivationTime

t

0

wReleaseTime

L_BRK

bQSP_b

bOut_b

bMStore_b

bCInh_b

nMSetOut_a

CTRL

Abb. 2−1

Holding brake (L_BRK)

VariableName

DataType

SignalType

VariableType

Note

bSet_b

Bool

binary

VAR_INPUT

nNx_a

Integer

analog

VAR_INPUT

Speed threshold from which the drive can output the
signal "close brake". The signal source for this input
can be a control code, a fixed value or any other
analog output of a FB.

nSign_a

Integer

analog

VAR_INPUT

Direction of the torque which the drive has to build up
against the brake. The signal source for this input can
be a control code, a fixed value or any other analog
output of a FB.

bQSP_b

Bool

binary

VAR_OUTPUT

QSP can be triggered in conjunction with MCTRL.

bOut_b

Bool

binary

VAR_OUTPUT

Set the brake

bMStore_b

Bool

binary

VAR_OUTPUT

provide a defined holding torque

bCInh_b

Bool

binary

VAR_OUTPUT

A controller inhibit can be set in conjunction with
DCTRL.

nMSetOut_a

Integer

analog

VAR_OUTPUT

Holding torque of the DC injection brake
16384 = value of C0057 (max. possible torque for the
drive configuration)

wReleaseTime

Word

VAR CONSTANT RETAIN

Brake disengaging time

wActivationTime

Word

VAR CONSTANT RETAIN

Brake engaging time

nMSet

Integer

VAR CONSTANT RETAIN

Holding torque

DCTRL_bCInh_b

Bool

These signals are processed as quantities within the
FB.

MCTRL_nNAct_a

Integer

MCTRL_nNSet2_a

Integer

MCTRL_nMAct_a

Integer

Parameter codes of the instances

VariableName

L_BRK1

SettingRange

Lenze

wReleaseTime

C0196

0.0 ... 60.0 s

0.0

wActivationTime

C0195

0.0 ... 99.9 s

99.9

nMSet

C0244

−199.99 ... 199.99 %

0.00