7 maintenance, Maintenance intervals, Maintenance operations – Lenze ERBM100R035W User Manual

Page 40: Maintenance, 7maintenance

Advertising
background image

7

Maintenance

Maintenance intervals

EDKRBM002 DE/EN/FR 4.0

40

l

H1_wart−BrmWidReinigen

7

Maintenance

Maintenance intervals

The brake resistor is maintenance−free. Nevertheless, a visual
inspection must be executed in short and regular intervals
considering the ambient conditions.

Ensure that:
ƒ the environment of the brake resistor still corresponds to

the operating conditions included in the technical data.

ƒ no dust or dirt impedes the heat dissipation of the brake

resistor.

ƒ the mechanical and electrical connections are correct.

Maintenance operations

Cleaning the brake resistor

1. Disconnect the standard device from the mains and wait at

least three minutes.

2. Check temperature of the brake resistor and allow it to cool,

if required.

3. Check the brake resistor for safe isolation from supply.
4. Clean brake resistor without using cleaning agents.

Advertising
This manual is related to the following products: