Troubleshooting and fault elimination, System error messages general error messages – Lenze 9300 0.37kW-11kW User Manual

Page 37

Advertising
background image

Troubleshooting and fault elimination

System error messages

General error messages

4

l

37

EDKVS93−01 EN 3.0

Remedy

Cause

Description

Fault message

Remedy

Cause

Description

Display

No.

x053

OH3

Motor temperature
> +150

C threshold

(temperature detection via
resolver or incremental value
encoder)

Motor is thermally overloaded
due to:

l

Impermissible continuous
current

l

Frequent or too long
acceleration processes

l

Check drive dimensioning.

l

Switch off monitoring
(C0583 = 3).

No PTC/temperature contact
connected.

Correct wiring.

x054

OH4

Heatsink temperature > C0122

Ambient temperature T

u

> +40

C

or > +50

C

l

Allow module to cool and
ensure better ventilation.

l

Check ambient temperature in
the control cabinet.

l

Switch off monitoring
(C0582 = 3).

Heatsink is very dirty.

Clean heatsink

Wrong mounting position

Change mounting position.

The value specified under C0122
is set too low.

Enter a higher value under C0122.

x057

OH7

Motor temperature > C0121
(temperature detection via
resolver or incremental value
encoder)

Motor is thermally overloaded
due to:

l

Impermissible continuous
current

l

Frequent or too long
acceleration processes

l

Check drive dimensioning.

l

Switch off monitoring
(C0584 = 3).

No PTC/temperature contact
connected.

Correct wiring.

The value specified under C0121
is set too low.

Enter a higher value in C0121.

x058

OH8

Motor temperature via inputs T1
and T2 is too high.

Motor is thermally overloaded
due to:

l

Impermissible continuous
current

l

Frequent or too long
acceleration processes

l

Check drive dimensioning.

l

Switch off monitoring
(C0585 = 3).

Terminals T1 and T2 are not
connected

Connect PTC/temperature
contact.

x061

CE0

Automation interface (AIF)
communication error

Faulty transfer of control
commands via AIF.

l

Plug in the communication
module/keypad XT firmly,
screw down, if necessary.

l

Switch off monitoring
(C0126 = 3).

x062

CE1

Communication error on the
process data input object
CAN1_IN

CAN1_IN object receives faulty
data or communication is
interrupted.

l

Check wiring at X4.

l

Check sender.

l

Increase monitoring time
under C0357/1, if necessary.

l

Switch off monitoring
(C0591 = 3).

x063

CE2

Communication error on the
process data input object
CAN2_IN

CAN2_IN object receives faulty
data or communication is
interrupted.

l

Check wiring at X4.

l

Check sender.

l

Increase monitoring time
under C0357/2, if necessary.

l

Switch off monitoring
(C0592 = 3).

x064

CE3

Communication error on the
process data input object
CAN3_IN

CAN3_IN object receives faulty
data or communication is
interrupted.

l

Check wiring at X4.

l

Check sender.

l

Increase monitoring time
under C0357/3, if necessary.

l

Switch off monitoring
(C0593 = 3).

Advertising