Parameter setting – Lenze EVS93xx User Manual

Page 22

Advertising
background image

Parameter setting

Parameter setting with the XT EMZ9371BC keypad
Display elements and function keys

3

l

22

EDKVS93−02 EN 3.0

4 Number

Active level

Meaning

Explanation

Menu level

Menu number

Display is only active for operation with
standard devices of the 8200 vector or 8200
motec series

Code level

Four−digit code number

5 Number

Active level

Meaning

Explanation

Menu level

Submenu number

Display is only active for operation with
standard devices of the 8200 vector or 8200
motec series

Code level

Two−digit subcode number

6 Parameter value

Parameter value with unit

7 Cursor

In the parameter level, the digit above the cursor can be directly changed

8 Function keys

For description see the following table

Function keys

)

Note!

Shortcuts with

T:

Press and hold

T, then press the second key in addition.

Key

Function

Menu level

Code level

Parameter level

Operating level

V

Change to the
parameter level

Change to the operating
level

Change to the code
level

T V

Go to the "Short setup"
menu and load
predefined
configurations

1)

Accept parameters
when SHPRG

p or

SHPRG is displayed

z

y

Change between menu
items

Change of code number

Change of digit via
cursor

T z

T y

Quick change between
menu items

Quick change of code
number

Quick change of digit
via cursor

Z

Change between main menu, submenu and code
level

Cursor to the right

Y

Cursor to the left

U

Deactivate the function of the key

S, the LED in the key goes off

S

Inhibit the controller, the LED in the key is lit.

Reset fault (TRIP−Reset): 1. Remove the cause of malfunction

2. Press

S

3. Press

U

1)

Only active for operation with standard devices of the 8200 vector or 8200 motec series