Troubleshooting and fault elimination, System error messages general error messages – Lenze VS9332−xx User Manual

Page 42

Advertising
background image

Troubleshooting and fault elimination

System error messages
General error messages

4

l

42

EDKVS93−03 EN 3.0

Remedy

Cause

Description

Fault message

Remedy

Cause

Description

Display

No.

x162

P12

Error in the range of the encoder.

The range of the absolute encoder
was exceeded.

l

Return drive by manual
positioning.

l

Check position limits and
adjustment of the encoder.

l

Design and mount the
absolute encoder in a way that
does not exceed the traversing
range.

x163

P13

Angle overrun.

l

Phase controller limit reached

l

Drive cannot follow the digital
frequency (I

max

limit).

l

Enable drive

l

Check drive dimensioning.

x164

P14

1. Following error.

The drive cannot follow the
setpoint. The following error is
greater than the limit value in
C1218/1.

l

Increase current limit under
C0022 (observe max. motor
current).

l

Reduce acceleration.

l

Check drive dimensioning.

l

Increase limit value under
C1218/1

x165

P15

2. Following error.

The drive cannot follow the
setpoint. The following error is
greater than the limit value in
C1218/2.

l

Increase current limit C0022
(observe max. motor current).

l

Reduce acceleration.

l

Check drive dimensioning.

l

Increase limit value under
C1218/2

x166

P16

Faulty transfer of system bus
(CAN) sync telegram.

The sync telegram from the
master (PLC) is out of sync cycle.

l

Set the "sync cycle" to the
transmission cycle of the
master (PLC) under C1121.

l

Note:
– C0362 displays the time

interval between 2 sync
telegrams.

– C0362 = 0: communication

interrupted.

The sync telegram of the master
(PLC) is not received.

l

Check communication channel.

l

Check baud rate, controller
address.

l

Note:
– C0362 displays the time

interval between 2 sync
telegrams.

– C0362 = 0: communication

interrupted.

The controller is enabled too fast.

Delay the controller enable.
The time delay required depends
on the time interval between the
sync telegrams.

x167

P17

Error "touch probe control".

Various function blocks use the
touch probe input at the same
time (e.g. FB DFSET and POS). A
conflict arises.

l

Configure another touch probe
input for FB POS (not possible
for FB DFSET).

l

Switch off monitoring
(C1289/1).

Advertising