4 technical data, General data and operating conditions, Technical data – Lenze ERBMxxxRxxxx User Manual

Page 31

Advertising
background image

Technical data

General data and operating conditions

4

EDKRBM470R DE/EN/FR 5.0

31

l

H1_Daten−Abm_BL

4

Technical data

General data and operating conditions

Conformity and approval

Conformity

CE

2006/95/EC Low−Voltage Directive

Approval

UR

UL508

Industrial Control Equipment,
Underwriter Laboratories (File−No.
E232497) for USA and Canada

Protection of persons and equipment

Enclosure

IP50

Thermal contact

Design

NC contact, 130 °C

Switching
capacity

250 V AC / 4 A
500 V AC / 2 A

Environmental conditions

Climate

Storage

IEC/EN
60721−3−1

1K3 (−25 ... +60 °C)

Transport

IEC/EN
60721−3−2

2K3 (−25 ... +70 °C)

Operation

IEC/EN
60721−3−3

3K3 (−10 ... +55 °C)
Current derating from +45 ... +55 °C:
2.5 %/°C

Site altitude

0 ... 4000 m amsl
1000 ... 4000 m amsl: Current
derating 5 %/1000 m

Vibration
resistance

(9.81 m/s

2

= 1 g)

EN 50178,
IEC
61800−5−1,
Germanisch
er Loyd,
general
conditions

Acceleration resistant up to 1 g

Mounting conditions

Mounting location

l

In the control cabinet

l

The mounting location must
comply with the device features
mentioned in the chapter
"General data".

l

Flammable materials or
substances may not be placed in
the vicinity of the brake resistor.

l

The heat generated by the brake
resistor must be dissipated
freely.

Mounting position

Vertically suspended with
connecting cables at the bottom.

Free space

at the top

> 200 mm

at the bottom

> 100 mm

to the sides

> 50 mm

Advertising