Mounting steps, 6electrical installation – Lenze ERBMxxxRxxxx User Manual

Page 36

Advertising
background image

6

Electrical installation

Mounting steps

EDKRBM470R DE/EN/FR 5.0

36

l

H1_E_INST−eInstall_EN

Variant 2: with cable extension

R

B

<5m

<

0.1

m

PE

PES

PES

ERBMXXX014

HF−shield termination by extensive PE connection

Twisted cables

Mounting steps

0

0

2

1

ERBMXXX013

How to connect the brake resistor:
1. Disconnect the basic device from the mains and check all

power terminals for safe isolation from supply.

2. Connect brake resistor cables

0 (RB1, RB2: red flexible) and

thermal contact cable

1 (T1, T2: blue flexible) (see

documentation for the basic device).
– If the prepared connecting cables are long enough, twist

them. (See connection plan, variant 1)

– If longer cables are required (max. 5 m), shorten the

prepared cables to at least 10 cm and connect them to
external terminal connections. From there on, use
shielded cables. (See connection diagram, variant 2)

– When integrating the thermal contact into the system

monitoring ensure that the mains supply will be
switched off when the brake resistor is overheated.

3. Connect PE cable to blade terminal

2 (6.3 x 0.8 mm).

– Implement PE connection according to EN 61800−5−1.