Flts, Hall, Curr – Lenze S94CAN01A User Manual

Page 8

Advertising
background image

6

ENGLISH

6

ENGLISH

Technical Data

Adr_

E94 Drive address. This address is only for RS232/RS485 communications. It

doesn’t affect the CANBUS Network. This parameter is R/W and can be between 0
and 31. Press the “ENTER” button ( ) to view address setting. Use the “UP” (

▲)

and “DOWN” (

▼) buttons to change the setting. Press the “ENTER” button ( ) to

store your setting and to exit. Press the “DOWN” (

▼) button to continue.

FLtS

E94 Drive Fault History. This parameter is Read only. Press the “ENTER” button (

) to view. Use the “UP” (

▲) and “DOWN” (▼) buttons to scroll through the fault

history. Press the “ENTER” button ( ) to exit. Press the “DOWN” (

▼) button to

continue.

Ht__

E94 Drive Heatsink Temperature. This parameter is Read only and shows heatsink

temperature in °C if greater than 40°C. Otherwise the display show “

LO” (low).

Press the “ENTER” button ( ) to view. Press the “ENTER” button ( ) again to
exit. Press the “DOWN” (

▼) button to continue.

EnC_

E94 Drive Encoder Activity. This parameter is Read only and shows primary

encoder counts for encoder diagnostics activity. Press the “ENTER” button ( ) to
view. Press the “ENTER” button ( ) again to exit. Press the “DOWN” (

▼) button

to continue.

HALL

E94 Drive Hall Activity. This parameter is Read only and displays the motors Hall

sensor state. Press the “ENTER” button ( ) to view. Press the “ENTER” button (
) again to exit. Press the “DOWN” (

▼) button to continue.

bUS_

E94 Drive DC Bus Voltage. This parameter is Read only and displays the DC bus

voltage value. Press the “ENTER” button ( ) to view. Press the “ENTER” button (

) again to exit. Press the “DOWN” (

▼) button to continue.

CUrr

E94 Drive Phase Current. This parameter is Read only and displays the current

value of the motors phase current (RMS) while the drive is enabled. If the drive is
disabled the display will show “

diS”. Press the “ENTER” button ( ) to view. Press

the “ENTER” button ( ) again to exit. Press the “DOWN” (

▼) button to continue.

Advertising