Function library, Function blocks, Convpha3 – Lenze EVS9332xK User Manual
Page 145: Function, Conversion with adaptation using divisor, Conversion according to formula
Advertising

Function library
Function blocks
3−117
l
EDSVS9332K−EXT EN 4.0
CONVPHA3
CONVPHA3
CONVPHA3-OUT
C1617
± 199,99%
CONVPHA3-IN
C1616
2
C1615
1
Fig. 3−89
Function block CONVPHA3
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
CONVPHA3−IN
ph
C1617
dec [inc]
C1616
3
−
CONVPHA3−OUT
a
−
−
−
−
Limited to
±199.99 %, remainder not considered
Function
l
Conversion with adaptation using divisor.
l
Conversion according to formula:
CONVPHA3–OUT
+ CONVPHA3–IN @
1
2
C1615
@ 100%
16384