Function library
Function blocks
3.2.93
Storage block (STORE1)
3−296
l
EDSVS9332K−EXT EN 4.0
Outputting the difference of the two angle signals saved
l
A two−stage counter controls the output at STORE1−PHDIFF.
l
Every second triggering via the TP input E5 results in a new output at STORE1−PHDIFF.
l
STORE1−LOAD0 = HIGH resets the counter.
Additional control
1. STORE1−LOAD1 = LOW−HIGH edge resets the counter to the 1st stage (preparation of the
output at STORE1−PHDIFF).
2. Triggering via the TP input E5 sets the counter to the 2nd stage (output at STORE1−PHDIFF is
effected).
)
Note!
If STORE1−LOAD1 is set cyclically, STORE1−PHDIFF outputs a new differential
signal after each triggering process.