Checking the configuration
Check a new or changed configuration in manual operation with regard to
a faultless function.
}
Danger!
Uncontrolled motor movement possible.
Incorrect settings in the configuration may cause uncontrolled
movements.
Possible consequences:
ƒ
Severe injuries to persons in or near the machine.
ƒ
The machine is damaged or destroyed.
Protective measures:
ƒ
Provide suitable emergency off equipment so that you are
able to shut down the drive immediately.
1
2
3
4
5
6
Fig. 6.10−2
"Control" dialog box
Procedure
1.
Activate "Manual operation" (3).
2.
Click "Start" (4) to enable the controller.
l
If "Ok" is displayed in the "Drive diagnostics" field (5), controller enable can be
executed.
l
Controller inhibit must be deactivated (X5/28 = HIGH).
3.
Move the drive against the travel range limit switches, in order to check its function.
l
"Pos. manual" (2) or "Neg. manual" (1) is activated: The drive traverses.
l
"Pos. manual" (2) or "Neg. manual" (1) is deactivated: The drive stops.
A
Activate "Pos. manual" (2).
l
The drive traverses in the direction of the positive travel range limit switch.
B
Activate "Neg. manual" (1).
l
The drive traverses in the direction of the negative travel range limit switch.