Configuration, Basic configurations – Lenze EVS9332xP User Manual
Page 345

Configuration
Basic configurations
8.5
l
8.5−79
EDSVS9332P EN 5.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C1670 CMPPH1−
FUNCTION
1
1
2
3
4
5
6
IN1 = IN2
IN1 > IN2
IN1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|
CMPPH1
Selection of the function for
comparing two phase signals
See system
manual
(extension)
C1671 CMPPH1−
HYSTERESIS
50
0
{1 inc}
1073741824 CMPPH1
Hysteresis to compensate an
oscillating output signal due to
unstable input signals
C1672 CMPPH1−
WINDOW
0
0
{1 inc}
1073741824 CMPPH1
Window within which the
phase signals comply with each
other
C1673
s
® Selection list 3 CMPPH1
Configuration of input signals
1 CMPPH1−IN1
1000
FIXED0INC
2 CMPPH1−IN2
1000
FIXED0INC
C1674
g
−2147483647
{1 inc}
2147483647 CMPPH1
Display of input signals
1 CMPPH1−IN1
2 CMPPH1−IN2
C1675 CMPPH2−
FUNCTION
1
1
2
3
4
5
6
IN1 = IN2
IN1 > IN2
IN1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|
CMPPH2
Selection of the function for
comparing two phase signals
See system
manual
(extension)
C1676 CMPPH2−
HYSTERESIS
50
0
{1 inc}
1073741824 CMPPH2
Hysteresis to compensate an
oscillating output signal due to
unstable input signals
C1677 CMPPH2−
WINDOW
0
0
{1 inc}
1073741824 CMPPH2
Window within which the
phase signals comply with each
other
C1678
s
® Selection list 3 CMPPH2
Configuration of input signals
1 CMPPH2−IN1
1000
FIXED0INC
2 CMPPH2−IN2
1000
FIXED0INC
C1679
g
−2147483647
{1 inc}
2147483647 CMPPH2
Display of input signals
1 CMPPH2−IN1
2 CMPPH2−IN2
C1680 CMPPH3−
FUNCTION
1
1
2
3
4
5
6
IN1 = IN2
IN1 > IN2
IN1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|
CMPPH3
Selection of the function for
comparing two phase signals