IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C1286
0
2
3
4
TRIP
Warning
Off
Fail−QSP
Monitoring P14, P15
^ 8.31
1 MONIT P14
4
1. following error tolerance
> C1218/1
2 MONIT P15
3
2. following error tolerance
> C1218/2
C1287
4
0
4
TRIP
Fail−QSP
P06 monitoring
No reference
^ 8.31
1 MONIT P06
C1288
4
0
2
3
4
TRIP
Warning
Off
Fail−QSP
P12 monitoring
Exceeding the encoder range
1 MONIT P12
C1289
0
2
3
4
TRIP
Warning
Off
Fail−QSP
Monitoring P17, P18
^ 8.31
1 MONIT P17
4
Control error of touch probe
2 MONIT P18
2
Internal limitation (display
area, position limits, speeds)
C1290
0
2
3
4
TRIP
Warning
Off
Fail−QSP
P16 monitoring
Configuration of monitoring in
the case of a sync error
^ 8.31
1 MONIT P16
4
C1291
0
4
TRIP
Fail−QSP
Monitoring P07, P08, P09
^ 8.31
1 MONIT P07
4
PS mode absolute instead of
relative
2 MONIT P08
4
Actual reference dimension
offset outside position limits
3 MONIT P09
4
Impermissible programming
C1292 MONIT P19
2
0
TRIP
P19 monitoring
Configuration of monitoring a
limitation of the input value at
DFIN
2
Warning
3
Off
C1298 P18
DIAGNOSTIC
g
0
1
2
3
4
5
6
No P18 source
C1223
C1224
C1240
C1250
V_norm
A_norm
P18 diagnostics
Display of the code which has
led to an internal limitation
^ 8.31
C1299
g
0
{1 pcs}
65535 POS
Display of actual state of piece
counter
See system
manual
(extension)
1 ACT. CNT
2 ACT. CNT
... ...
32 ACT. CNT
C1301
−214000
,0000
{0.0001 units}
214000,
0000
POS
Entry of VTPOS position values
See system
manual
(extension)
1 VTPOS−VALUE
0
2 VTPOS−VALUE
0
... ...
...
60 VTPOS−VALUE
0