5] el 5] 5] 5, Lanze – Lenze 490 Series Speed controllers tor DC motors User Manual

Page 16

Advertising
background image

page: 13

quick stop,

see chapter 8

output armature current signal

The output terminal ~

supplies a signal proportional to

the armature current.

(U

31)

=

5V corresponds approxi—

mately to the nominal current of the controller and can
be used for the direot current display with a measuring
instrument.
The maximum bad

of terminal ~

is

bOmA.

3

GND

Speed

controller

input

Terminal ~

leads to the summation point of the

speed

controller via Ri

50 k[2.

The permissible

input voltage

range is between +10V and -10V.

When switching the

controller inhibit the input is

switched to

zero.

In

this oase Ri ~ 25 k[2.

For positive set value or positive

master voltage and negative actual value a positive

armature voltage is applied at terminal A.

GND, controller reference point

input,

current control,

Ri ~ 10 kfi

output speed controller,

Ri ~ 200 fl.

The terminals ~

and

are connected internally via the resistor R 705

on soldering posts.

For current ratio

control or

connection of an external current potentiometer this
resistor must be removed.

The desired maximum armature

current is set using the internal trimmer 1

with

fully

open external current potentiometer.

39

1.

durrerit set value 10 k/1 W Im
Remove R705

5]
El

5]

5]
5]

Lanze

Advertising