17

12.2 Mains choke

Type

part no

L

1

m

mli

in.

b

c

mii in.

imi in.

i

imi in.

m

mii

in.

492 LK

322 149

3x1.2 mM 3x17 A 120

4.7

66 2.6 110 4.3

53 2.1

162

6.3

493

322 148

3x1.1 mM 3x25 A 150

5.9

753.01405.5

602.8 180

7.0

494 LK 307 343

3x750 LII

3x45 A 180

7.0

85 3.3 163 6.4

69 2.7 218

8.5

495 L

K

307 346

3x270 LII 3x105A 228

9.0 107 4.2 207 8.1

91 3.6 273 10.7

496 LK 308 234 3x165 LH 3x170A 264 10.4 128 5.0 240 9.4 104 4.0 260 10.2

LK

=

commutating choke

(mains choke)

12.3 Power losses

Series

492

493

494

495

496

Pv/W
current controller

60

108

185

288

577

Pv/W
mains and armature fuse

18

33

63

112

140

Pv/W
mains choke

30

55

80

130

170

13.

Iteus supplied

Installedfield and electronic fuses,

set value potentiometer 10 kfi

You must order separately:

mains choke
knob and scale for set value
potentiometer, mains fuses,
armature fuse and fuse holder