Lanze – Lenze 490 Series Speed controllers tor DC motors User Manual
Page 17
![background image](/manuals/566150/17/background.png)
ct~eaJc~a4:
03.11.89
EK12/fa
page:~
14
output standstibb logic
nmax
When the speed is bess than n
=
50
the transistor output terminab
~j
switches to =0.6V
When instabbing a diode
(e.g.
1N4004)
on the position
V 714 of the board 4091,
the transistor output terminab
~
switches to
0.6 V if the speed is bess than
nmax
n
=
and the motor
is without current.
50
The output
is used for an automatic mains switch—off.
-
Application proposab for fastest possibbe mains
switch-off
(faster
braking in inverter operation).
V174 must be sobdered.
See chapter
11.
REL/TRP-1 5
part no.
321 351
K3
tBr brake time
of the
drive
S1
drive off
S2
drive on
K2
reiay with goid—piated contacts
5]
+Vcc
=
15V stabibized
maximum external bad of +Vcc is
50 mA
10.
Optical display of the most iinpartant functions with LEDs
10.1 LED ±Vcc
±Vcc is
bit,
when the controbber
is
ready to operate.
±Vcc is not bit when there is no power suppby
(±Vccsurveillance).
Lanze
5]
IOOR
10K
BC 337
quick stop deloyed
n1~n ccn~octcr
r~Oy
timer
cur~ent conTro!Ier