Installation

L

68

EDBEPM-H520 DE/EN/FR 4.0

Take off the housing cover

0

1

2

3

4

5

+24 VDC

N.C.

0 VDC

CAN+

N.C.

Shield

CAN-

V-

1

2

3

4

INPUT VOLTAGE:

18 - 32 VDC 15 W

fuse 1.25 A

MSP

LPT

back-up expansion

h520_009

Fig. 3-3

Take off the housing cover

1.

Loosen bolts

&

and remove housing cover

Flash module 8 MB (back-up) mounting

LPT

A

C

B

h520_012

Fig. 3-4

Flash module 8 MB (back-up) mounting

1.

Insert the distance pins

'

into the bores of the main board and press until they click into place

2.

Carefully insert the flash module

&

into the female plug strip

)

and slightly press to fix them

3.

Align the bores of the flash module

&

and the distance pins

'

4.

Press the flash module

&

onto the distance pins

'

until they click into place