Installation of the E93ZWL air lock

Preparations at the top of the control cabinet

10

l

E93ZWLX DE/EN/FR 1.0

3.4.3

Fix air lock to controller and to top of control cabinet

2

1

0

3

4

5

4

5

93ZWL018



Self-cutting screw



Air lock



Spring washer M6



Mounting plate



Top of control cabinet



Hexagon socket screw M6 × 16 mm

z

Fix the air lock to the top of the control cabinet using 16 self-cutting screws.

z

Fix the air lock to the controller exactly at the illustrated points using 2 hexagon socket screws
and spring washers.

3.4.4

Ground air lock

0

1

2

3

1

2

4

3



‚

93ZWL22



Top of control cabinet



Spring washer M6



Grounding conductor of control
cabinet (not part of the items



Tooth lock washer M6



Hexagon socket screw M6 × 16 mm

cabinet (not part of the items
supplied)

1. Ground the air lock exactly at the illustrated point of the controller using 1 hexagon socket

screw, spring washer and tooth lock washer.

2. Ground the air lock exactly at the illustrated point of the control cabinet using 1 hexagon

socket screw, spring washer, grounding conductor and tooth lock washer.