181

6

I/O terminals

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6

I/O terminals

This chapter provides information on the function, possible parameter settings, and technical data

of the input/output terminals of the controller.
Which input and output terminals are available depends on the communicaton unit used:

In the »Engineer«, the digital and analog input and output terminals are parameterised on the Ter-

minal assignment tab. To do this, go to the Control terminals list field and select the terminals that

you wish to parameterise:

You can find further information in the respective subchapter:

Digital terminals

( 182)

Analog terminals

( 188)

Communication unit

Digital terminals

Relay

output

Analog

input

Safety

ext. 24 V

RFR

DI

DO

No fieldbus

simple

1

2

-

1

-

-

-

Standard

1

5

1

1

1

-

-

Extended

1

8

1

1

2

-

-

CANopen option

simple

1

5

1

-

-

-

-

Safety STO

1

5

1

1

1

1

-

AS-i option

simple

1

5

1

-

-

-

1

Safety STO

1

5

1

1

1

1

1

EtherCAT option

simple

1

5

1

-

-

-

1

Safety STO

1

5

1

1

1

1

1

EtherNet/IP™ option

simple

1

5

1

-

-

-

1

Safety STO

1

5

1

1

1

1

1

PROFIBUS option

simple

1

5

1

-

-

-

1

Safety STO

1

5

1

1

1

1

1

PROFINET option

simple

1

5

1

-

-

-

1

Safety STO

1

5

1

1

1

1

1

Detailed information on the respective "CAN" communication unit can be found in the

corresponding online help and in the communication manual (KHB).

Note!

The input and output terminals of the controlelr are already functionally assigned in the

default setting ("Lenze setting"). The preconfigured assignment depends on the control

mode selected in

C00007

.

Terminal assignment of the control modes

( 214)