C00680 | l_compare_1: fct, C00681 | l_compare_1: hysteresis, C00682 | l_compare_1: window – Lenze 8400 motec User Manual

Page 392: 11 parameter reference

Advertising
background image

11

Parameter reference

11.2

Parameter list | C00680

392

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00680

C00681

C00682

Parameter | Name:

C00680 | L_Compare_1: Fct.

Data type: UNSIGNED_8

Index: 23895

d

= 5D57

h

The

L_Compare_1

FB: Comparison operation

• If the statement of the selected comparison operation is true, the binary bOut output will be set to TRUE.

Selection list

(Lenze setting printed in bold)

1 In1 = In2
2 In1 > In2
3 In1 < In2
4 |In1| = |In2|
5 |In1| > |In2|
6 |In1| < |In2|

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00681 | L_Compare_1: Hysteresis

Data type: INTEGER_16

Index: 23894

d

= 5D56

h

The

L_Compare_1

FB: Hysteresis for the comparison function selected in

C00680

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

%

100.0 0.5 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00682 | L_Compare_1: Window

Data type: INTEGER_16

Index: 23893

d

= 5D55

h

The

L_Compare_1

FB: Window for the comparison function selected in

C00680

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

%

100.0 2.0 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100